Graco GLC 2200 Instructions Manual page 20

Lubrication controller
Hide thumbs Also See for GLC 2200:
Table of Contents

Advertisement

Advanced Programming (Series E or later models only)
1.The word A1:OF appears in the display.
Press the UP or DOWN ARROW button
to change this to A1:ON.
2.The cursor is automatically positioned to
entered the first character of the PIN
Code. Use the UP and DOWN ARROW
buttons to move up and down through the numbers
0-9 until the first number in the PIN code is dis-
played in the field.
3.Press the ENTER button to set the num-
ber. The cursor automatically moves
to the next number field.
4.Repeat steps 2 and 3 for each PIN Code prompt field.
5.Press the ENTER button to set the PIN Code and exit
Advanced Setup.
A2 - Pulsed Setup
Programs ON and OFF time in MM: SS (minutes and
seconds) for pump operation during a normal pump on
cycle.
1.To set the ON time use the UP or DOWN
ARROW button to scroll through
numerals 0 to 9 until the desired num-
ber appears in the first MM (minutes)
field.
2.Press the ENTER button to set the num-
ber. The cursor automatically moves
to the next number field.
3.Repeat Steps 1 and 2 until all MM:SS fields are pro-
grammed.
4.Repeat Steps 1 - 3 to program the OFF time.
NOTE: If the pulse mode is enabled, the pump ON led
will blink for the duration of the pulse ON time while the
pump is on in Run Mode. The pump ON led will remain
solid during the Run Mode for the duration of the pulse
OFF time.
A3 - Auxiliary Output Setup
Allows the use of the alarm output during normal pump
ON cycle.
20
1.The word A3:ON appears in the display.
Press the UP or DOWN ARROW button
to cycle between A3:ON and A3:OF.
2.Press the ENTER button to save and
exit setup.
•When the Auxiliary Output is
enabled, the output will remain
powered during the Pump ON cycle whether or
not the main pump output is pulsing.
•When the Auxiliary Output is not enabled (OFF) the
alarm output will operate as an alarm output.
3A2960F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Glc 2200 24n468

Table of Contents