Graco GLC 2200 Instructions Manual page 13

Lubrication controller
Hide thumbs Also See for GLC 2200:
Table of Contents

Advertisement

2.Press ENTER.
3.To set the ON time use the UP or
DOWN ARROW to scroll through
the numerals 0-5 until the desired number appears
in the first Minutes (MM) field.
NOTE:
•The MM field is a 2-digit number.
•A leading zero (0) must be entered in the first field if
the number of minutes is fewer than 10.
•The highest number that can be set for the MM field
value is 59.
4.Press the ENTER button.
The next MM number field to the right flashes, indicating
it is ready for programming.
5.Use the UP or DOWN ARROW to scroll through the
numerals 0-9 until the desired number appears in
the second MM number field.
6.Press the ENTER button.
The next number field to the right flashes indicating it is
ready to program the Seconds (SS) fields.
NOTE:
•The Seconds (SS) field is a 2-digit number.
•A leading zero (0) must be entered in the first field if
the number of seconds is fewer than 10.
•The highest number that can be set for the SS field
value is 59.
7.Repeat steps 3 - 6 to set the SS fields.
8.Press the ENTER button. After you press the ENTER
button the controller automatically switches to the
OFF TIME SETUP MODE.
3A2960F
Backup Time
In both Cycle and Pressure Modes, a maximum run
Time (Backup Time) for the lubrication period must be
set up. If this Time expires before the lubrication is com-
pleted an alarm/warning is triggered and the pump
stops.
To determine the Backup Time, Graco recommends the
user verify the length of time it takes to complete a typi-
cal cycle and double that value.
Backup Time is setup after Cycle or Pressure Sensor
Setup is complete.
NOTE:
•The LED below the clock in the ON field
lights, indicating the Backup Time is being
programmed.
•BACKUP (ON) Time is set as minutes and seconds
(MM:SS) only.
•The small flashing LED under the MM indicates you are
setting minutes.
•The first field (left side of display) blinks indicating the
device is ready for you to begin programming.
Programming Backup Time
NOTE: When programming a time of less than 10 min-
utes you must program the leading zero in the first num-
ber field and press the ENTER button.
1.To set the ON Time use the UP or DOWN
ARROW button to scroll through numer-
als 0 to 5 until the desired number
appears in the first MM (minutes) field.
2.Press the ENTER button. The next MM
number field to the right flashes indi-
cating it is ready for programming.
3.Use the UP or DOWN ARROW button to
scroll through numerals 0 to 9 until the
desired number appears in the second
MM number field.
Setup
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Glc 2200 24n468

Table of Contents