14 | Lap Trigger
14.3.3 Distance based forced trigger
92 / 112
Change signal for vehicle speed,
if desired.
Enter minimum speed for
trigger release.
Define settings for distance
based retrigger protection.
Define settings for distance
based forced trigger.
Main Trigger
After a missed main trigger, a forced trigger is inserted, if the configured max. distance
(i.e. 120 % → 4800 m) of the track distance (i.e. 4000 m) has been reached. In this case, the
channel 'Laptrigger_distlap_dls' starts at the delta between the max. distance and the track
distance (i.e. 800 m).
To deactivate distance based forced triggers, uncheck box.
Change signal for vehicle speed,
if desired.
Enter minimum speed for
trigger release.
Define settings for distance
based retrigger protection.
Define settings for distance
based forced trigger.