Bosch C 70 Manual page 17

Hide thumbs Also See for C 70:
Table of Contents

Advertisement

Bosch Motorsport
Drag + Drop
A 'Multipoint Adjustment Wizard' opens.
4.
To activate the internal pullup-resistor, check the box. The internal pullup-resistor is
used to get a 5 V signal at the analog channel of the C 70. It allows you to use a push-
button. The fixed value of the internal pullup-resistor is 3.01 kOhm. If using an addi-
tional external pullup-resistor, set up the overall resistance.
5.
Click 'Next' when done.
The second part of the 'Multipoint Adjustment Wizard' opens.
Data Logger C 70 Manual
Analog and Frequency Inputs | 5
17 / 112

Advertisement