See Figure 52 on page 90.
Figure 52. 9006-22P PCIe adapter positions
Position
1 (UIO Slot2), 2 (UIO Slot1)
4 (WIO-R Slot)
3 (WIO Slot1), 5 (WIO Slot2), 6 (WIO Slot3)
3. To install a PCIe adapter in position 1 or 2, remove the PCIe riser as shown in Figure 53 on page 90.
Figure 53. Removing the PCIe riser
a) Retract the retaining pin (A) as shown in Figure 53 on page 90.
b) Lift the PCIe riser from the system.
c) Place the PCIe riser on an ESD surface.
d) Remove the screw and the tail-stock filler for that position.
e) If you are inserting a storage drive adapter, connect the signal cables to the adapter before
inserting the adapter.
90 Power Systems: Installing and configuring the IBM Power System LC922 (9006-22P)
Step
"3" on page 90
"4" on page 92