Instructions for fitting connectors, attachments and devices
2.5 Power supply
2.5.2

Fitting a 7/8" energy connector to an energy cable

Design
Figure 2-5
Suitable cables
7/8" energy connectors are intended for making connections to the SIMATIC NET energy
cable (5 x 1.5 mm
wire-end ferrules.
Note
The mechanical data of the 7/8" energy connector are tailored to the SIMATIC NET energy
cables (6XV1 830-8AH10). Fitting 7/8" energy connectors to cables with different electrical or
mechanical properties can cause problems during operation!
Connecting up the bus cable
Fit the energy connector to the energy cable (6XV1 830-0AH10) as follows:
72
7/8" energy connector
). The stranded wires of the energy cable must be fitted with 0.75 mm²