Instructions for fitting connectors, attachments and devices
Insert the data module and the splice element into the
supplied IDC assembly tool.
Press the data module and the IDC assembly tool
together to establish the installation piercing connection.
Remove the assembled data module from the IDC
assembly tool.
Position the top shield plate and press it over the cable
shield.
2.3 Electrical networks