6. Put the sealing ring into the rear wall
and screw the forcing nut over it
loosely.
7. Turn the latch of the rear wall to the
same side as the red coding bars of
the plug insert.
8. Push the rear wall as far as the limit
stop of the plug insert.
Dismantling the plug
1. To open the plug, lever the catch in the
housing towards the side wall with a
slotted screwdriver.
2. Pull the rear wall out of the housing by
the cable while holding down the
screwdriver.
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01
Instructions for fitting connectors, attachments and devices
9. Turn the latch of the rear wall
and the notch in the housing to
the same side.
10. Push the housing over the plug
insert as far as the limit stop.
3. Press open the cage springs
with a slotted screwdriver.
4. Pull the wires out of the contact
clamps one by one.
2.5 Power supply
11. Press the rear wall into the housing
until it clicks in place audibly.
12. Screw the pressure nut tight.