Instructions for fitting connectors, attachments and devices
2.3 Electrical networks
7. To strip the insulation, turn the tool
in the direction of the arrow
approx. 4 times for PVC
insulation
approx. 8 times for PUR
insulation
10. Spread out the cores according to
their colors on the contact holder of
the FC RJ-45 plug 180 4x2.
11. Cut off the filler thread as close to
the shield braid as possible.
20
8. Keeping the it closed, pull the
stripping tool with jacket and
remnants of the shield off the end of
the cable.
Note: If a core is damaged, the section
of cable must be cut off and stripped
again.
12. Insert the wires into the contact
element of the FC RJ-45 plug 180 4
x 2 as far as the limit stop according
to the color markings.
9. Remove the cable jacket, shield
and the white filler with your hand.
13. Press down the contact element as
far as the limit stop.
Notes: If the wires do not completely
fill the wire guide slits, the cable must
be stripped again.
If the wires extend beyond the wire
guide slits, the wires must be
shortened.
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01