Assembly Of Industrial Twisted Pair Connectors; Assembling Industrial Twisted Pair Connectors - Siemens 6GK1 901-1GB01 System Manual

Passive network components. industrial ethernet / profinet
Table of Contents

Advertisement

Instructions for fitting connectors, attachments and devices
2.3 Electrical networks
2.3.11

Assembly of Industrial Twisted Pair connectors

2.3.11.1

Assembling Industrial Twisted Pair Connectors

General
To maintain the excellent EMC and transmission characteristics of the twistedpair cabling
system, connectors must be fitted with extreme care.
Note the assembly instructions.
How to fit 9pin and 15pin connectors is explained in detail on the following pages.
Note
Instructions for assembly
Fit the D-sub plugs for self-assembly only to the ITP standard cable or the ITP FRNC cable.
The cable clamp used for contacting the shield is designed for the diameter of this cable.
The two ITP cables are not suitable for connection to the IE FC outlet RJ-45, IE FC RJ-45
plug and IE FC RJ-45 modular outlet due to their diameters. Use the FastConnect (FC)
twisted pair cables for this.
46
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6gk1 901-1ga006gk1 901-1gb00

Table of Contents