Parameter Level 1 - Viessmann Vitodens 100 Series Installation And Service Instructions Manual

6.5 to 35.0 kw wall mounted gas condensing boiler. natural gas version
Table of Contents

Advertisement

Main parameter level
Standby mode
Symbols
Flashing
constant

Parameter level 1

Calling up parameter level 1:
1. Hold down MODE and
neously for approx. 5 s.
■ "SEt" and
flash.
■ "PL:1" is shown on the additional
display.
is shown in the upper display
area
Emissions test mode
Parameter Possible change
"P01"
"OFF" Test mode switch-
"On"
With test mode switched
on, use
tween upper and lower
heating output.
Filling and venting function
Parameter Possible change
"P02"
"OFF" Function switched
"On"
(cont.)
Main display
"SEt"
simulta-
ed off
Test mode switch-
ed on
/
to change be-
off
Function switched
on
Additional display
2. Press MODE.
■ "P01" is shown on the main dis-
play.
is shown and does not flash.
3. Use
/
to select the parameter.
4. OK to confirm
Main display
With test mode
switched on:
■ Temperature
in °C
Main display
With test mode
switched on:
■ "Air"
Parameter
Additional display
With test mode
switched on:
"LO" For lower
heating out-
put
"HI" For upper
heating out-
put
Additional display
With test mode
switched on:
■ Remaining time
in min
57