Specification - Viessmann Vitodens 100 Series Installation And Service Instructions Manual

6.5 to 35.0 kw wall mounted gas condensing boiler. natural gas version
Table of Contents

Advertisement

Specification

Specification
Gas condensing system boiler
Type
Rated heat input (heating mode)
Rated heat input (DHW heating)
Rated heating output in heating
mode (T
/T
50/30 °C)
F
R
Rated heating output during DHW
heating (T
/T
80/60 °C)
F
R
Sound power level
At full load (100 %)
At partial load (30 %)
Efficiency
At full load (100 %)
■ T
/T
80/60 °C
F
R
■ T
/T
50/30 °C
F
R
At partial load (30 %) T
50/30 °C
Gas throughput relative to max.
heating output
Natural gas 12T
Gas supply pressure
Natural gas 12T
NOx class
Power consumption
Max.
Without circulation pump
Boiler water capacity
Diaphragm expansion vessel
Capacity
Pre-charge pressure
Permiss. operating pressure
(heating water side)
Min.
Max.
Heating water temperature
Min.
Max.
DHW temperature
Min.
Max.
102
dB (A)
dB (A)
/T
F
R
LN1GBQ
18-CC
kW 6.1 – 17.8 6.1 – 24.3
kW 6.1 – 17.8 6.1 – 24.3
kW
6.5 – 19
kW 5.9 – 17.3 5.9 – 23.7
< 49
< 37
%
99.0
%
106.5
%
105.9
1.9
3
m
/h
Pa
2000
5
W
81
W
20
l
2.8
l
6
MPa
0.1
MPa
0.08
MPa
0.3
°C
20
°C
80
°C
30
°C
60
LN1GBQ
LN1GBQ
24-CC
33-CC
8.2 – 32.7
8.2 – 32.7
6.5 – 26
8.8 – 35
8.0 – 31.9
< 49
< 37
99.5
107.0
106.9
106.5
105.6
2.6
2000
2000
5
113
30
2.8
6
0.1
0.08
0.3
20
80
30
60
< 49
< 40
98.0
3.5
5
141
42
3.4
6
0.1
0.08
0.3
20
80
30
60

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents