NEW EXCALIBUR
P15
P17
repLACING THe pUMp UNIT HOUsING Upper GAsKeT
•
Remove the piston stem (p18) from the pump unit housing
(p19) as shown.
www.larius.eu
24
P16
P18
P19
•
Unscrew the gasket compression ring nut (p20) completely.
All the gaskets in the unit must be replaced at the same
time to allow the machine to work properly.
•
Remove the upper stainless steel female ring (p21) as
shown.
P21
P20
P21
Ed. 015 - 02/2019