Pit Stop Maintenance; Replacing The Foot Valve Seals - Larius NEW EXCALIBUR Operating And Maintenance Instruction Manual

Electric piston pump
Hide thumbs Also See for NEW EXCALIBUR:
Table of Contents

Advertisement

Disconnect the pumping group by unscrewing the fastening
nut (wrench 45).
Unscrew the pumping group from the housing.
You can now work easily as the pump casing has been freed.
Grip the complete pump unit (p9) in a vice (p10) (as shown).
Slacken the ring nut (p11) by two full turns using the special
pin (p12) supplied.
Turn anticlockwise as shown.
P11
P12
Use a 36 mm spanner to unscrew the pump unit as shown.
Ed. 015 - 02/2019
Remove the pump unit (p13) from the foot valve (p14) as
P10
shown.
Inspect the two parts separately.
P9

pIT sTOp MAINTeNANCe

Replacement of upper and lower gaskets 25 minutes.

repLACING THe FOOT VALVe seALs

Replace the PTFE gasket (p15) located under the ball
seating (p16).
Check that the surfaces of the ball seating (p16) and the
ball (p17) are not damaged. If necessary, replace both of
them.
Fit them again using the component sequence shown.
NEW EXCALIBUR
P13
P14
www.larius.eu