Correct Procedure Of; Decompression - Larius NEW EXCALIBUR Operating And Maintenance Instruction Manual

Electric piston pump
Hide thumbs Also See for NEW EXCALIBUR:
Table of Contents

Advertisement

O

COrreCT prOCeDUre OF

DeCOMpressION

Insert the gun clamp (O1).
O1
Move the switch (O2) to the OFF position to stop the
equipment.
Reduce pressure to the minimum (turn counterclockwise
the pressure control knob (O3)).
O2
Ed. 015 - 02/2019
Clamp inserted
Clamp released
OFF
O3
Disconnect the power supply cable (O4).
Release the gun clamp (O1), point the gun into the tank
of the product and press the trigger to release pressure.
At the end of the operation, insert the gun clamp.
Open the recirculating-safety valve (O5) to release the
residual pressure always clockwise.
O5
WARNING :
If the equipment is still under pressure after perfor-
ming the operations above described because of
the nozzle or the flexible hose clogged, proceed
as follows:
Loosen very slowly the gun nozzle.
release the clamp.
point the gun into the container of the product
and press the trigger to release pressure.
Loosen very slowly the fitting of connection
from the flexible hose to the gun.
Clean or replace the flexible hose and the
nozzle.
NEW EXCALIBUR
O4
www.larius.eu
21