Siemens Cerberus CS1140 Planning page 43

Fire detection system
Hide thumbs Also See for Cerberus CS1140:
Table of Contents

Advertisement

CT11
(operation = separate C-Bus station)
Õ Details see page 42
C-Bus
24V
Battery
charging mdule
CPU
E3X10.
Driver
1..........8
1..2
24V
Z3B171
RT
250V
10A
AC
Fire control
installations
Modules H67G601 and H67G611
Control and operation
E3X101
546674
Master module
K3N010
522818
RAM extension card
Z3S070
504823
RAM set 2x512Kx8Bit
E3X102
629025
Master module
E3X103
629038
Master module
B3Q...
Control terminal AlgoPilot
H26T...
Plexiglass door to AlgoPilot B3Q...
Z5B...
......
Inscription set
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
EPROM sets and Flash programm files
CCQ00xxx 577627
EPROM set to 'CC1142'
CCW00xxx 577630
EPROM set to 'CC1143'
CCX00xxx (OSS)
Flash programm file
CCY00xxx (OSS)
Flash programm file
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Õ according to detector series
Line modules
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
LON module
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Õ
Control modules
if more than 7 progr. control outputs are required
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Extinguishing modules and operation
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Õ as far as the space available allows installation
Interfaces
E3H020
546658
Gateway 'CERLOOP'
E3I020
460239
RS232 module
K3I090
510820
Pager interface
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Õ for calculation of the emergency power operating period see page 91
Power supply
B2F020
470588
Converter 115/230V
B1F120
495233
Converter 115/230V
AX1201
225487
Battery 12V/27Ah
AX1209
462936
Battery 12V/42Ah
Z3I450
484273
Mains socket "CH"
Z3I041
496290
Surge protector set
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Cabinet/Accessories
H67G601 495550
Cabinet set 'Door without cutout'
H67G611
495660
Cabinet set 'door with cutout'
H67G620 577863
Cabinet set for marine
H67E101
509705
Module chassis compl. for H67 ...
H23B010
476210
Cover
H23B040
484590
Information module
B3Q321
565684
Fire department control terminal "CH"
B3R051
490513
Parallel indicator terminal "2x24 indicators"
Z3I350
475538
Cable set for H47/H67
Z3I380
475567
I-Bus flat cable + supply cable "long"
Z1I040
475512
Connection cable 9 cond. with card holder, 0.8m
Z1I050
475525
Connection cable, 19 cond. with card holder, 0.8m for internal pre-wiring
Z1I070
525815
Connection cable, 4 cond. with card holder, 0.8m
Z3B171
484383
Relay module 1 x 250VAC/10A
Z3I330
475156
Terminal block, 2x20 terminals
Z3I420
483818
Intermediate connecting terminal block
Z3I570
495644
Support rail 'TS35' 133 mm with bracket
Z3G270
566120
Marinekit
Pre-configured cabinet
CC1142-NL 547000
Control unit in H67 housing
Fire & Security Products
Siemens Building Technologies Group
42
Batteries
B2F020
AX12..
24V
E3I020
K3I090
or
RS232
1
2
external printer
Printer
Pager
–> see page 82
–> see page 86
>29.6V
6A
AC
DC
>24V
3A
AC
DC
RT = Remote transmission
Mains
I-Bus
E3L030
FBF
FSK
HM
internal or
VdS peripheral
equipment
EPROM and RAM set separately
1MB-RAM additional to E3X101
to E3X101
Flash-ROM and 1MB-RAM equipped
Flash-ROM and 2MB-RAM equipped
all variants of the AlgoPilot Õ see page 42
optional Õ see page 42
according to language Õ see page 45, 46
for Main CPU E3X101
for Main CPU E3X101 with K3N010
for Main CPU E3X102
for Main CPU E3X103
for details referring line modules Õ see page 59
for details referring floor indicator terminal Õ see page 72
for details referring control modules Õ see page 66
for details referring extinguishing Õ see page 79
double Europe card (requires 2 module spaces) Õ see page 75
for connection of printer B2Q191 or non-Cerberus printer
for connection of paging system/pager and internal/external printer
generally for fire control system supply
option
for details referring cabinets Õ see page 55
for separate control terminal
for installation in control terminal
for installation in external cabinets
essential or H23B040 or B3Q321 or B3R051
brief operating instructions
only CH
option
essential
to connect module level 4.. with level 3..
for internal pre-wiring
for internal pre-wiring
intermediate relay for fire control installations
for additional free terminals
for up to 8 Z3B171 relays
pre-configured for 'NL' requirements
CC11
E3G...
E3I040
E3M...
E3L...
LON-Bus
LON synoptic converter
LON I/O card
Floor indicator terminal
–> see page 72ff
Basic equipment
Option
42/43
K3I050
K3I110
B3Q580/
B3Q59x
37
e4595e 14
05.2003

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents