Siemens Cerberus CS1140 Planning page 33

Fire detection system
Hide thumbs Also See for Cerberus CS1140:
Table of Contents

Advertisement

C-Bus
24V
24V
5V
AlgoPilot
B3Q...
E3I020
or
K3I090
RS232
1
2
internal or
Printer
external printer
–> see page 82
Pager
–> see page 86
Modules H38G220
Control and operation
B3Q...
Control terminal AlgoPilot
H26T...
Plexiglass door to AlgoPilot B3Q...
Z5B...
Inscription set
E3G070
546661
Control module 'universal'
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Õ according to detector series
Line modules
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
LON module
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Õ if more than 7 programmable control outputs are required
Control modules
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Õ as far as the space available allows installation
Interfaces
E3H020
546658
Gateway 'CERLOOP'
E3I020
460239
RS232 module
K3I090
510820
Pager interface
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Õ for calculation of the emergency power operating period see page 91
Power supply
B2F020
470588
Converter 115/230VAC>29.6VDC 6A
E3C011
505479
Battery charging unit
AX1210
475570
Battery 12V/15Ah
Z3I460
484312
Mains socket 'CH'
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Cabinet/Accessories
H38G220 484914
Cabinet set 'door with cutout'
H23B010
476210
Cover
H23B040
484590
Information module
Z3I470
484341
Cable set for H38...
Z3I380
475567
I-Bus flat cable + supply cable 'long'
Z1K030
484231
Terminal block with p.c.b. chassis for CI11..
Z3B171
484383
Relay module 1 x 250VAC/10A
Fire & Security Products
Siemens Building Technologies Group
CT11
42
(additional operating facilities)
Õ Details see page 42
Mains
E3C011
B2F020
24V
E3G070
1........7
1..2
24V
Z3B171
RT
250V
Fire control
installations
RT = Remote transmission
Akkus
AX1210
I-Bus
E3M...
10A
AC
all variants of the AlgoPilot Õ see page 42
option Õ see page 42
according to language Õ see page 45, 46
for alarm devices and control outputs
for details referring line modules Õ see page 59
for details referring floor indicator terminal Õ see page 72
for details referring control modules Õ see page 66
double Europe card (requires 2 module spaces)
for connection of printer B2Q191 or non-Cerberus printer
for connection of paging system/pager and internal/external printer
for details referring cabinets Õ see page 53
essential or H23B040
brief operating instructions instead of H23B010
essential
required for connection from level to level (e.g. Pos 28 ↔ 38)
required for each module (E3H020 2x)
intermediate relay for fire control installations (max. 6)
Basic equipment
Option
CI11
42
E3G...
E3I040
E3L...
LON-Bus
K3I050
K3I110
LON synoptic converter
LON I/O card
B3Q580/
Floor indicator terminal
B3Q59x
–> see page 72ff
27
e4595e 10
05.2003

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents