After Installing Belt Cleaner And Tensioner - Martin QC1 Operator's Manual

Cleaner xhd with metal tipped blade.
Hide thumbs Also See for QC1:
Table of Contents

Advertisement

After Installing Belt Cleaner
Martin Engineering M3722-11/12
1. Thoroughly wipe chute wall clean above tensioner.
2. Place Conveyor Products Warning Label (P/N 23395) on outside chute
wall visible to belt cleaner operator.
Failure to remove tools from installation area and conveyor
belt before turning on energy source can cause serious injury
to personnel and damage to belt.
Do not touch or go near conveyor belt or conveyor accessories
when conveyor belt is running. Body or clothing can get
caught and pull body into conveyor belt, causing severe injury
or death.
3. Turn on conveyor belt for 1 hour, then turn off.
Before installing, servicing, or adjusting the belt cleaner/
tensioner, turn off and lock out/tag out all energy sources to
the conveyor and conveyor accessories according to ANSI
standards. Failure to do so could result in serious injury or
death.
4. Make sure all fasteners are tight. Tighten if necessary.
5. Inspect belt cleaner for the following:
• Wear. (A small amount of "break-in" wear may be found. This will
stop once blades wear to conveyor belt contour.)
• Material buildup. (No material between blades and return side of
conveyor belt should be found.)
6. If wear, material buildup, or some other problem exists, see
"Troubleshooting."