OPERATOR'S CARD
P/N 1017461C
r
Sure Coat
Operator Interface
WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions
in this document and all other related documentation.
The operator interface consists of an LCD and eight keys. Use the interface to program and operate the
triggering controller.
Edit/Configure Keys
Key
Function
Mode
MODE
Select
+ and -
+
SELECT
OK
OK
(Enter)
Undo
Triggering Controller
Press to:
toggle modes: run,
language, setpoint
adjustment, and
configure.
navigate through mode
menus, or to increase or
decrease values when in
edit mode.
to enter edit mode, again
to set value and exit edit
mode.
cancel value change and
exit the edit mode.
Operation Keys
Key
Function
Auto
Manual
Off
1
Press to:
put controller in automatic
mode. Spray guns
triggered according to
controller settings and
signals received from
sensors and encoder.
put controller in manual
mode. Spray guns
triggered continuously.
turn off spray guns.
Controller continues to
monitor parts moving
p
g
through booth.
h
h b
h

Advertisement

loading

Summary of Contents for Nordson Sure Coat

  • Page 1 Nordson Corporation OPERATOR’S CARD P/N 1017461C Sure Coat Triggering Controller Operator Interface WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. The operator interface consists of an LCD and eight keys. Use the interface to program and operate the triggering controller.
  • Page 2 Accessing and Changing Controller Settings Accessing Configuration and Setpoint 4. Press the OK key to accept the value and exit edit mode. Menus 1. Press the MODE key until the desired mode Changing Interface Language appears. 2. Press the OK key to enter the mode. NOTE: The default interface language is English.
  • Page 3 Extend signal to eliminate signal chatter when coating wire goods, delay signal to skip hangers. Outputs Choose 4, 6, or 8 trigger outputs. Use 4 or 8 for Sure Coat Modular Gun Control System, 6 for Sure Coat Mini Stack System, and 4, 6, or 8 for Versa-Spray systems.
  • Page 4 Calibrating the Triggering Controller 1. Choose a test part. It can be a production part or 10. Start the conveyor. a piece of cardboard. It will not be coated. As the part moves through the photoeyes the 2. Measure the part length as it is hung on the controller measures it in counts.
  • Page 5 Calculating Lead and Lag Values Value Description Positive or Negative Values Lead Lead is the distance from the Positive Lead: Setting the lead to a positive value turns on the spray guns to the leading spray guns before the leading edge of the part reaches them. edge of the part.
  • Page 6 Setting Trigger Points (contd) Error Factor Effect on Spray Patterns Entering Trigger Points Use the following steps to enter pickoff, lead, and lag The triggering controller has an error factor of one values for each trigger output. real-world unit. For example, if the controller scale is inches, the error factor is one inch.
  • Page 7: Normal Operation

    Press the Nordson oval to find out which condition exists. 1 2 3 4 A B C D B C D 1400257A Figure 4 Run Mode Display Issued 5/03 Original copyright date 2001. Nordson, the Nordson logo, and Sure Coat are registered trademarks of Nordson Corporation.