Arbonia Sabiana Energy Smart Series Installation, Use And Maintenance Instructions page 21

Appliances for residential ventilation
Table of Contents

Advertisement

Connection with remote control
The control is provided by default fitted on the appli-
ance, however it can also be remoted by fitting it on
the wall.
Always disconnect power
before accessing the unit.
1- Remove the controller from the front panel using
the suction cup accessory.
2- Remove the 3-pole connector coupled to the controller.
1
1a
2
3) Unscrew the top cover to access the electric com-
partment where the power board is located.
3
4) Remove the cable connected to the "CONTROL"
connector (terminals 1-2-3) of the power board.
4
CONTROL
5) Perform the new connection to position the con-
troller on the wall, respecting the sequence of the
terminal numbers:
a) apply the supplied cable gland as indicated in the
figure;
b) fix the cable in the cable gland;
c) connect the cable to terminals1-2-3 from the power
board to the controller respecting the numbers;
1 2 3
PG7
CONTROL
English
21