- Condensate drain connection
The connection for the condensate drain is located
underneath the appliance:
Connect the condensate drain to the domestic sewage
system using a duct or pipe (siphoned).
Condensate must be drained from a minimum height
of 100 mm.
PLEASE NOTE: if you choose the version with right
side connection, invert the condensate drain plug (see
paragraph "How to change connection").
1 1/2 " G
Attention! Make sure that the siphon of the
condensate drain connected to the
domestic sewer system is always full of water.
Attention! Make sure that the end of the
siphon is at least 100 mm below the water
level.
Y
FLOOR INSTALLATION OF APPLIANCE
- OPTIONAL ACCESSORY-
As an alternative, the residential ventilation appliance
can be installed using the floor stands.
- Fixing the stands
4
1
3
2
M8 x 20
1 - Fix the stands(1) using the screws (2) and washers
(3),supplied with the accessory, at the bottom of the
appliance (4). Fasten the crossbar (5) to the support (1).
2 - Lift the unit and position it vertically
3 - Use a spirit level to check the position of the ap-
pliance.