Quantum StorNext QM1200 Replacing Manual page 9

Base system, a controller
Hide thumbs Also See for StorNext QM1200:

Advertisement

StorNext QM1200, QS1200 or QS2400 Base System - Replacing a Controller
2.
Locate the battery within the controller
Figure 7 Battery and Locking Handle in the Controller
3.
On the failed controller with the battery, perform these steps:
a.
Release the latch that secures the battery to the controller.
b.
Remove the battery by sliding it towards the rear of the failed controller.
c.
Lift the battery slightly upward as you slide it to the rear of the failed controller.
NOTE You will insert this battery into the new controller.
4.
If Small Form-factor Pluggable (SFP) transceivers are present, record the ports in which they are installed, and
remove them.
5.
Insert the battery that you removed from the failed controller into the serviceable controller.
a.
Slide the battery from the back of the controller toward the front.
b.
Insert the battery at a slight downward angle into the controller canister.
1.
Top Cover Latch Buttons
2.
Battery Circuit Board
3.
Battery Latch
(Figure
7).
Quantum Corporation
- 7 -
April 2015

Advertisement

loading

This manual is also suitable for: