Mounting; Dimension Drawing - Siemens SINUMERIK 828D PPU Series Manual

Hide thumbs Also See for SINUMERIK 828D PPU Series:
Table of Contents

Advertisement

Connectable components
7.1 MCP 483C PN
LED for status display
When the system is booting, all three LEDs are lit.
Name
Designation
H1
PowerOK
H2
PNSync
H3
PNFault
7.1.2

Mounting

7.1.2.1

Dimension drawing

The 483C PN machine control panel is ideally combined with a horizontal PPU. The
recommended combination sequence is shown in the figure:
MCP 483C PN dimension drawing
Figure 7-4
102
Color
Description
Green
Lit: Power supply OK
Green
Lit: System software running, STOP state
Flashes 0.5 Hz: System software running, RUN state
Red
Not lit: Module is operating without errors; data exchange with all configured IO Devices
is running.
Lit: Serious bus fault; only output when one of the following errors is detected for the
ports:
No physical connection to a subnet/switch
Incorrect transmission rate
Full duplex transmission is not activated
Front and side view of MCP 483C PN
Manual, 11/2010, 6FC5397-2DP10-1BA0
PPU

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d ppu 24 2 basic t seriesSinumerik 828d ppu 24 2 basic m seriesSinumerik 828d ppu 240.2 basic mSinumerik 828d ppu 240.2 basic tSinumerik 828d ppu 241.2 basic tSinumerik 828d ppu 241.2 basic m ... Show all