DMX model 227
4
Installation
4.1 Installation Information
Picture of optimal installation:
1
V3.0
8
2
6
4
3
12
11
p
10
6
For dosing media which tend to sedimentation:
13
6 Overflow valve
10 Injection unit
9
7
10
5
For easy deaeration of the pump:
Install a ball valve (11) with bypass line (back to the dosing tank)
immediately behind the pressure valve
In case of long pressure lines:
Install a check-back valve (12) into the dosing line.
Keep the suction line as short as possible, avoid a tangled suction
line
•
If necessary, use swept bends instead of elbows.
Always lay the suction line rising to the suction valve of the dosing
pump.
•
Avoid loops which cause air bubbles.
For non-degassing media with viscosity similar to water, the pump
can be mounted onto the tank (observe the admissible suction
height).
Preferably flooded suction.
Install a suction line with filter (13) in a way ensuring that the suction
valve remains several centimetres a bove the botton of the tank.
1
Dosing tank 502
2
Electric agitator 509
3
Extraction device 521
4
Suction pulsation damper 516
5
Dosing pump
6
Overflow valve 525
7
Pressure retention valve 525
8
Pulsation damper 517
9
Measuring glass
10
Injection unit 522