Installation; Installation Information - Grundfos DMX Series Installation And Operating Instructions Manual

Diaphragm dosing pump, model 227
Table of Contents

Advertisement

DMX model 227
4

Installation

4.1 Installation Information

Picture of optimal installation:
1
V3.0
8
2
6
4
3
12
11
p
10
6
For dosing media which tend to sedimentation:
13
6 Overflow valve
10 Injection unit
9
7
10
5
For easy deaeration of the pump:
Install a ball valve (11) with bypass line (back to the dosing tank)
immediately behind the pressure valve
In case of long pressure lines:
Install a check-back valve (12) into the dosing line.
Keep the suction line as short as possible, avoid a tangled suction
line
If necessary, use swept bends instead of elbows.
Always lay the suction line rising to the suction valve of the dosing
pump.
Avoid loops which cause air bubbles.
For non-degassing media with viscosity similar to water, the pump
can be mounted onto the tank (observe the admissible suction
height).
Preferably flooded suction.
Install a suction line with filter (13) in a way ensuring that the suction
valve remains several centimetres a bove the botton of the tank.
1
Dosing tank 502
2
Electric agitator 509
3
Extraction device 521
4
Suction pulsation damper 516
5
Dosing pump
6
Overflow valve 525
7
Pressure retention valve 525
8
Pulsation damper 517
9
Measuring glass
10
Injection unit 522