Start Time; Voltage Limit Values For Neutral Conductor Monitoring - Fronius IG Plus USA Operating Instructions Manual

Field adjustable trip points
Table of Contents

Advertisement

Frequency
Unit
Limit Values
Setting range
(continued)
Factory setting

Start Time

Unit
Setting range
Factory setting
Voltage Limit
The voltage limit values for neutral conductor monitoring are only shown
Values for
at the following grids:
Neutral Con-
-
ductor Monito-
-
ring
Unit
Setting range
Factory setting
Unit
Setting range
Factory setting
Important
limit voltage. This corresponds to the 'inner limit voltage trip time' set for
the voltage limit values:
-
-
P (grid cycles)
1 - 17998 at 208 V / 240 V / 277 V grid voltage
9 at 208 V / 240 V / 277 V grid voltage
s
5 - 900
300
208 V with neutral conductor (Setup: 208VN)
240 V with neutral conductor (Setup: 240VN)
V
62 - 143
132
V
61 - 142
106
The time in which the system can exceed or fall below the
for 'U
' ... 'U
Max
NMON
TRIP
for 'U
' ... 'U
Min
NMON
TRIP
Start initiation time
Grid monitoring time during the startup phase
During this time, the inverter checks the
power grid to determine whether or not all
values are within tolerances during the star-
tup phase. If any values deviate from the
tolerance range, the inverter disconnects
from the power grid.
Maximum neutral conductor monitoring
voltage
Upper limit voltage between phase and neu-
tral conductor
Minimum neutral conductor monitoring
voltage
Lower limit voltage between phase and neu-
tral conductor
'
Max
'
Min
7