Restoring the System,
Run SHOW
CONFIG
Command
Note
Run the
System
Exerciser
3–22
Continued
To run the SHOW CONFIG command, complete the following
steps and refer to Example 3–1.
Step
Action
1
Press the Halt button located behind the door in the front
of the system box.
Results: The system displays the console prompt on the
screen.
Enter SHOW CONFIG at the console prompt and press
2
.
Return
>>> SHOW CONFIG
3.
Verify the Ethernet hardware address. The address must
be the same as the one recorded before the upgrade
began. Refer to the section Preparing VAXstation
Model 60 for Disassembly for more information.
4.
Verify that the SPXg/gt diagnostic ROM is Version 1.2 or
higher.
The TURBOchannel adapter module and options are not
tested by test 100. For more information, refer to the
VAXstation 4000 Model 90 Service Information Guide.
Verify that all devices are interacting properly by using the TEST
100 command to run the system exerciser.
Return