Setup; Connect Power Cord - Graco XM Series Operation Manual

Plural-component sprayers
Hide thumbs Also See for XM Series:
Table of Contents

Advertisement

Setup

Connect Power Cord

(For sprayers with heater junction boxes.
Non-hazardous location sprayers only.)
Graco does not supply heater junction box power cords.
Use the following chart to determine which power cord
your specific model requires.
Power Cord Requirements
Voltage
Cord Specification AWG (mm
240V, 1 PH
4 (21.2) 2 wire + ground
240V, 3 PH
6 (13.3) 3 wire + ground
380V, 3 PH
6 (13.3) 4 wire + ground
NOTE:
Sprayers without heaters for non-hazardous locations
include a U.S. style NEMA 5-15 power cord and an
IEC-320 power cord. (European and Australian adapters
are also included.) These power cords are rated for
90-240 Vac, 47-63 Hz. See the XM Plural-Component
Sprayers Repair-Parts manual or the XM Plural-Compo-
nent OEM Sprayers Instructions-Parts manual for part
numbers.
NOTE:
Disregard terminal numbers on disconnect switch
blocks. Wire to positions shown.
1. Open junction box cover.
2. Connect electrical cord as follows.
312359J
230V, 1 Phase: Use a screwdriver to connect two power
leads to the top terminals N and L2 positions. Connect
green to ground (GND).
N
230V, 3 Phase Delta: Use a screwdriver to connect
three power leads to top terminals L1, L2, and L3. Con-
2
)
nect green to ground (GND).
N
380V, 3 Phase WYE: Use a screwdriver to connect three
power leads to the top terminals L1, L2, and L3. Connect
neutral to N. Connect green to ground (GND).
N
7L4
L1 L2 L3
1L1
ti8611a
L1 L2 L3
1L1
ti8612a
7L4
L1 L2 L3
1L1
ti8613a
Setup
PE
L1
L2
N
1
2
3
GRND
G
N L1 L2 L3
PE
L1 L2 L3
N
1
2
3
GRND
G
N L1 L2 L3
PE
L2 L3
N
L1
N
1
2
3
GRND
G
N L1 L2 L3
19