Intel xeon processor e5-2600 v3/v4 cpu sled (68 pages)
Summary of Contents for ADLINK Technology cPCIS-6130R Series
Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Page 2
Series 1U Height Subsystem for 6U CompactPCI User’s Manual Manual Rev. 2.01 Revision Date: December 26, 2006 Part No: 50-15011-100 Advance Technologies; Automate the World. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 3
Copyright 2005 ADLINK TECHNOLOGY INC. All Rights Reserved. The information in this document is subject to change without prior notice in order to improve reliability, design, and function and does not represent a commitment on the part of the manufacturer.
Page 4
Getting Service from ADLINK Customer Satisfaction is top priority for ADLINK Technology Inc. Please contact us should you require any service or assistance. ADLINK TECHNOLOGY INC. Web Site: http://www.adlinktech.com Sales & Service: Service@adlinktech.com TEL: +886-2-82265877 FAX: +886-2-82265717 Address: 9F, No. 166, Jian Yi Road, Chungho City,...
Table of Contents Table of Contents..............i List of Figures ................ iii 1 Introduction ................ 1 Features................1 General ................1 Boards Space ..............2 CompactPCI Compliancy ..........2 Enclosure ................ 2 Specifications............... 2 Mechanical Layout............... 3 Compatible CPU Modules ........... 4 Customized Systems ............
Page 7
cPCIS-6130R/DC4: APS-115XU ........26 Features ................ 26 Specifications ..............27 Output Characteristics ..........27 Mechanical Drawing ............. 27 Important Safety Instructions..........29 Warranty Policy ..............31 Table of Contents Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Introduction The cPCIS-6130R Series subsystem is designed for Telecom Data Center and Enterprise applications requiring a low profile PICMG 2.0 R3.0 CompactPCI compliant chassis with PICMIG 2.1 R2.0 hot swap support. The chassis is 1U height and standard 19” rack mount width for 6U cPCI cards, has a 2-slot board space, a hot swap backplane, a 64-bit/66MHz cPCI bus, and provides rear I/O for 80mm RTMs.
Boards Space Board space supports standard 6U height and 2-slot width Accommodates single or dual-slot system boards. Both front and rear access possible CompactPCI Compliancy PICMG 2.0 R3.0 CompactPCI Core Specification PICMG 2.1 R2.0 CompactPCI Hot Swap Enclosure EIA RS-310C 19” 1U high rackmount enclosure Coated metal plate outer covering 1.2 Specifications CompactPCI Standards PICMG 2.0;...
1.4 Compatible CPU Modules For complete systems, users must order CPU modules in addition to the subsystem. The following table lists which ADLINK Com- pactPCI CPU modules are compatible with the cPCIS-6130R Series models. CPU Module 64-bit/66MHz cPCI-6860A cPCI-6840 cPCI-6830 cPCI-6820 cPCI-6810 cPCI-6780...
Getting Started This chapter describes the unpacking procedure of the subsystem and installation procedures for CompactPCI boards and power supply units (PSUs), and hard drive rack operation procedures. 2.1 Shipping Contents Check the shipping carton for any damage. If the shipping carton and contents are damaged, please notify the dealer for a replace- ment.
The handles on CompactPCI cards and PSUs ensure simple and safe installation and removal. Please follow the procedures below to install a CompactPCI module into a chassis: 1. Place the subsystem on a level surface or rackmount it. Remove the blanking plates where required by undoing the retaining screws at each end.
4. Continue inserting the card until the handles engage with the chassis. 5. Pull inwards on the handles for final insertion. Ensure that the red buttons on the handles fully latch into posi- tion as unless this is done the card is not correctly inserted.
ATX power switch are turned on. Refer to the diagram below for LED and switch locations. cPCIS-6130R Series Figure 2-3: cPCIS-6130R Series switches and LED Getting Started Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Backplanes In this chapter, we will describe the backplane for the cPCIS- 6130R Series, the cBP-6402R. 3.1 Features Standard CompactPCI for 6U cPCI cards Suitable for one single-slot system module and one expan- sion card, or one dual system module. Supports 80mm rear I/O for each slot PICMG 2.1 Hot Swap compliant 64-bit 2-slot CompactPCI backplane with P3 &...
3.4 Connector and Jumpers Fan Connectors [Fan1 – Fan6] Signal V(I/O) Select [J1] Signal Signal V(I/O) V(I/O) +3.3V +3.3V (default: J4-J5 shorted – jumpers must be set in pairs) Power LED [J2] Signal Speaker [J3] Signal BUZZER Backplanes Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 21
ATX Power Connector [CN1] Signal Signal +3.3V +3.3V +3.3V -12V PS_ON_L PWRGOOD STB5V +12V ATX Power Switch [CN2] Signal Power On +5VSb Reset Button [CN3] Signal RESET# Backplanes Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 23
System Slot: [SYSP2] RVA43) RVB43 RVC43 RVE43 RVA42 RESET# RVA41 RVB41 RVE41 RVA40 FAL# AD [35] AD [34] AD [33] AD [32] AD [38] V (I/O) AD [37] AD [36] AD [42] AD [41] AD [40] AD [39] AD [45] V (I/O) AD [44] AD [43]...
Page 24
System Slot: [SYSP3] BUZZER Backplanes Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 25
System Slot: [SYSP4] 12-14 Keying Area Backplanes Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 26
System Slot: [SYSP5] Backplanes Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 28
Peripheral Slot: [P2] RVA43) RVB43 RVC43 RVE43 RVA42 RESET# RVA41 RVB41 RVE41 RVA40 AD [35] AD [34] AD [33] AD [32] AD [38] V (I/O) AD [37] AD [36] AD [42] AD [41] AD [40] AD [39] AD [45] V (I/O) AD [44] AD [43] AD [49]...
Cooling System The cPCIS-6130R Series subsystems are equipped with several fans to provide cooling for the system board, peripheral card and power supply unit. The intake fans have a replaceable air filter. Only cPCIS-6130R fan units are hot-swappable. Fan modules other than the front-access intake fan require the user to manually disconnect the power cable.
4. Place the filter back in position, replace the filter cover and screws, and reinstall the filter module into the chas- sis. 4.2 Fan Specifications SUNON KDE1204PKVX (right side intake fans x2 and rear exhaust fan x1) Dimensions: 40 x 40 x 20mm Weight: 30 g Type: DC brushless Rated voltage: 12V...
Power Supply Unit The power supply options for the cPCIS-6130R Series are as fol- lows: The cPCIS-6130R is equipped with the APS-120XU and the cPCIS-6130R/DC4 is equipped with the APS-115XU. Both are ATX power supplies. 5.1 cPCIS-6130R: APS-120XU Features Active PFC (full range), meet IEC-1000-3-2 CLASS D 12V Max.
Mechanical Drawing 5.2 cPCIS-6130R/DC4: APS-115XU Features DC –48V input 12V Max. current : 7A Temperature range: Operating 0? ~ 50? Humidity: Operating:20%-95%, Non-operating:10%-95% Remarks:85% is normal condition and 95% is with special coating process EMI noise filter: FCC CLASS A, CISPR22 CLASS A Safety: UL 1950, CSA 22.2 NO/ 950, TUV IEC 950 Cooling: One 40 mm DC fan Power Supply Unit...
Important Safety Instructions Please read and follow all instructions marked on the product and in the documentation before operating the system. Retain all safety and operating instructions for future use. Please read these safety instructions carefully. Please keep this User’s Manual for future reference. The equipment should be operated in an ambient tempera- °...
Page 39
Openings in the case are provided for ventilation. Do not block or cover these openings. Make sure there is adequate space around the system for ventilation when setting up the work area. Never insert objects of any kind into the ventila- tion openings.
Warranty Policy Thank you for choosing ADLINK. To understand your rights and enjoy all the after-sales services we offer, please read the follow- ing carefully. 1. Before using ADLINK’s products please read the user man- ual and follow the instructions exactly. When sending in damaged products for repair, please attach an RMA appli- cation form which can be downloaded from: http:// rma.adlinktech.com/policy/.
Page 41
3. Our repair service is not covered by ADLINK's guarantee in the following situations: Damage caused by not following instructions in the User's Manual. Damage caused by carelessness on the user's part dur- ing product transportation. Damage caused by fire, earthquakes, floods, lightening, pollution, other acts of God, and/or incorrect usage of voltage transformers.
Page 42
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Need help?
Do you have a question about the cPCIS-6130R Series and is the answer not in the manual?
Questions and answers