Record Of Use Check (1); Record Of Use Check (2); Record Of Self-Diagnosis Check - Sony DCR-TRV16 Service Manual

Digital video camera recorder
Table of Contents

Advertisement

DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E

8. Record of Use check (1)

Page 7
Note1: When replacing the drum assembly or the mechanism deck, initialize the data of address: A7 to A9.
Note2: This data will be kept even if the lithium battery (CK-108 board BT5201 of the cabinet (R) assembly) is removed.
Note3: The data of page: 0, address: 10 must be "00".
Address
A7
A8
Drum rotation counted time (BCD code)
A9
Using method:
1) The record of use data is displayed at addresses: A7 to A9.
Initializing method:
1) Select page: 7, address: 00, and set data: 71.
2) Select page: 7, address: 01, set data: 71 and press the PAUSE button.
3) Check that the data of page: 7, address: 02 is "00".

9. Record of Use check (2)

Page 7
Note1: This data will be kept even if the lithium battery (CK-108 board BT5201 of the cabinet (R) assembly) is removed.
Note2: The data of page: 0, address: 10 must be "00".
Address
C8
C9
User initial power on date (BCD code)
CA
CB
Final condensation occurrence date
CC
(BCD code)
CD
Using method:
1) The record of use data is displayed at addresses: C8 to CD.

10. Record of Self-diagnosis check

Page 7
Note1: This data will be kept even if the lithium battery (CK-108 board
BT5201 of the cabinet (R) assembly) is removed.
Note2: The data of page: 0, address: 10 must be "00".
Address
Self-diagnosis code
B0
"Repaired by" code (Occurred 1st time) *1
B1
"Block function" code (Occurred 1st time)
B2
"Detailed" code (Occurred 1st time)
B4
"Repaired by" code (Occurred 2nd time) *1
B5
"Block function" code (Occurred 2nd time)
B6
"Detailed" code (Occurred 2nd time)
B8
"Repaired by" code (Occurred 3rd time) *1
B9
"Block function" code (Occurred 3rd time)
BA
"Detailed" code (Occurred 3rd time)
BC
"Repaired by" code (Occurred 4th time) *1
BD
"Block function" code (Occurred 4th time)
BE
"Detailed" code (Occurred 4th time)
C0
"Repaired by" code (Occurred 5th time) *1
C1
"Block function" code (Occurred 5th time)
C2
"Detailed" code (Occurred 5th time)
C4
"Repaired by" code (Occurred the last time) *1
C5
"Block function" code (Occurred the last time)
C6
"Detailed" code (Occurred the last time)
*1 : "01" → "C", "03" → "E"
Address A7 to A9
Function
Hour (H)
Hour (M)
Hour (L)
Address C8 to CD
Function
Year
Month
Day
Year
Month
Day
Address B0 to C6
100000th place digit and 10000th place digit of counted time
1000th place digit and 100th place digit of counted time
10th place digit and 1st place digit of counted time
After setting the clock, set the date of power on next.
Using method:
1) The past self-diagnosis codes are displayed at addresses: BC
to C6. Refer to "SELF-DIAGNOSIS FUNCTION" for detail
of the self-diagnosis code.