Initialization Of E, F, 1F Page Data - Sony DCR-TRV16 Service Manual

Digital video camera recorder
Table of Contents

Advertisement

1-2-4.

INITIALIZATION OF E, F, 1F PAGE DATA

Note: When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
"00".
1. Initializing the E, F, 1F Page Data
Note1: If "Initializing the E, F, 1F Page Data" is performed, all
data of the E page, F page and 1F page will be initialized.
(It is impossible to initialize a single page.)
Note2: If the E, F, 1F page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F, 1F page data
2) 36MHz origin osc. adjustment
3) Camera system adjustments
Note3: The power supply voltage must be 6.0 ± 0.1Vdc.
Note4: NTSC model: DCR-TRV16/TRV18
PAL model: DCR-TRV16E/TRV18E/TRV116E/TRV118E
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
1F
Adjusting Address
00 to D9
Initializing Method:
Order Page Address Data
1
0
01
01
2
0
10
00
3
6
01
4
6
03
FF
5
6
02
6
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
Procedure
Set the data.
Set the data.
Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
Set the data, and press PAUSE
button.
Check that the data changes to
"01".
Perform "Modification of E, F,
1F Page Data".
2. Modification of E, F, 1F Page Data
If the E, F, 1F page data has been initialized, change the data of the
"Fixed data-2" address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1F page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1F page data, reset the
data of this address to "00".
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 1F Page data
Order Page Address Data
1
0
10
2
2
00
3
2
01
4
5-15
Procedure
00
Set the data.
29
Set the data.
29
Set the data, and press PAUSE
button.
Perform "36MHz Origin Osc.
Adjustment" of the camera
system adjustment.