5742640-TIM-A-0419
ZDT03 through TA6 - With Powered Convenience Outlet (Belt Drive High Static)
Compressors
Size
(each)
Volt
(Tons)
RLA LRA
4
208-1-60
15.4
83.9
4
230-1-60
15.4
83.9
208-3-60
10.4
73
T03
(3.0)
230-3-60
10.4
73
460-3-60
5.8
38
575-3-60
4.2
36.5
4
208-1-60
19.6
130
4
230-1-60
19.6
130
208-3-60
13.7
83.1
T04
(4.0)
230-3-60
13.7
83.1
460-3-60
6.2
41
575-3-60
4.8
33
24
OD Fan
Supply
Pwr
Motors
Blower
Conv
(each)
Motor
Outlet
MCC
FLA
FLA
FLA
24
2.3
6.7
10
24
2.3
6.7
10
16.3
2.3
4.3
10
16.3
2.3
4.3
10
9
1.3
2.1
5
5.9
1.3
1.9
4
30.5
2.3
6.7
10
30.5
2.3
6.7
10
21.4
2.3
4.3
10
21.4
2.3
4.3
10
9.7
1.3
2.1
5
7.5
1.3
1.9
4
Electric Heat Option
Model
kW
Stages
Amps
NONE
-
-
-
E05
4
1
19.2
E07
5.6
1
26.9
E10
8
1
38.5
E15
11.9
2
57.2
E20
15.9
2
76.4
NONE
-
-
-
E05
5.3
1
22.1
E07
7.5
1
31.2
E10
10.6
1
44.2
E15
15.9
2
66.2
E20
21.2
2
88.3
NONE
-
-
-
E05
4
1
11.1
E07
5.6
1
15.5
E10
8
1
22.2
E15
11.9
2
33
E20
15.9
2
44.1
NONE
-
-
-
E05
5.3
1
12.7
E07
7.5
1
18
E10
10.6
1
25.5
E15
15.9
2
38.2
E20
21.2
2
51
NONE
-
-
-
E07
6.8
1
8.2
E10
10.1
1
12.1
E15
13.6
2
16.4
E20
19.5
2
23.5
NONE
-
-
-
E10
10.6
1
10.2
E15
15.9
2
15.3
E20
21.2
2
20.4
NONE
-
-
-
E05
4
1
19.2
E07
5.6
1
26.9
E10
8
1
38.5
E15
11.9
2
57.2
E20
15.9
2
76.4
NONE
-
-
-
E05
5.3
1
22.1
E07
7.5
1
31.2
E10
10.6
1
44.2
E15
15.9
2
66.2
E20
21.2
2
88.3
NONE
-
-
-
E05
4
1
11.1
E07
5.6
1
15.5
E10
8
1
22.2
E15
11.9
2
33
E20
15.9
2
44.1
NONE
-
-
-
E05
5.3
1
12.7
E07
7.5
1
18
E10
10.6
1
25.5
E15
15.9
2
38.2
E20
21.2
2
51
NONE
-
-
-
E07
6.8
1
8.2
E10
10.1
1
12.1
E15
13.6
2
16.4
E20
19.5
2
23.5
NONE
-
-
-
E10
10.6
1
10.2
E15
15.9
2
15.3
E20
21.2
2
20.4
2
Max Fuse
/
1
3
MCA
Breaker
(Amps)
Size
(Amps)
38.3
50
44.9
50
54.5
60
69
70
92.4
100
116.4
125
38.3
50
48.5
50
59.9
60
76.1
80
103.7
110
131.3
150
29.6
40
31.8
40
37.3
40
45.6
50
59.2
60
73
80
29.6
40
33.8
40
40.4
45
49.7
50
65.7
70
81.6
90
15.6
20
19.1
20
24.1
25
29.3
30
38.2
40
12.2
15
20.1
25
26.5
30
32.9
35
43.5
60
44.9
60
54.5
60
69
70
92.4
100
116.4
125
43.5
60
48.5
60
59.9
60
76.1
80
103.7
110
131.3
150
33.7
45
33.7
45
37.3
45
45.6
50
59.2
60
73
80
33.7
45
33.8
45
40.4
45
49.7
50
65.7
70
81.6
90
16.1
20
19.1
20
24.1
25
29.3
30
38.2
40
12.9
15
20.1
25
26.5
30
32.9