Iid Module - State Water Heaters SandBlaster SBD71 120 Service Handbook

Sbd71 120 through sbd85 500
Table of Contents

Advertisement

CONDITION
DAMPER OPENS NO POWER
TO IID MODULE
PILOT LIGHTS, SPARKS
CONTINUOUSLY
HEATER WILL NOT IGNITE
WEEPING TEMPERATURE
AND
PRESSURE RELIEF VALVE
LARGE VOLUME WATER
RELIEF FROM T&P VALVE
PREMATURE TANK
LEAKAGE
DAMPER WILL NOT OPEN
NO SPARK AT PILOT -
DAMPER FULLY OPEN
Technical Training Department
Ashland City, TN ©2003
SBD TANK TYPE HEATERS
SERVICE HANDBOOK
GENERAL SERVICE CHART
CAUSE
. DAMPER NOT FULLY OPEN
. DEFECTIVE PROTECTOR
SWITCH
PILOT FLAME NOT PROVING
NOT PROVING PILOT
FLAME EXISTANCE
PILOT GAS NOT COMPLETELY
INTERRUPTED AT END OF
HEATING CYCLE
. THERMAL EXPANSION
. FAULTY VALVE
. EXCESSIVE WATER
TEMPERATURE
. FAULTY RELIEF VALVE
CONDENSATION
CONTAMINATED AIR
WATER HAMMER
THERMAL EXPANSION
DEPLETED ANODES
BINDING SHAFT
DAMPER MOTOR
DAMPER ASSEMBLY

IID MODULE

SPARK CABLE
.EFFIKAL – REPLACE DAMPER CONTROL
ASSEMBLY
. REPLACE DAMPER
. REPLACE PC BOARD
SEE FLAME RECTIFICATION - STEP 16
INTERRUPT 120 VAC POWER
. CHECK GROUND WIRE
ATTACHMENT
. CLEAN OR REPLACE PILOT
ASSEMBLY
. CHECK SUPPLY GAS PRESSURE
. REPLACE GAS VALVE
ADD THERMAL EXPANSION TANK
REPLACE RELIEF VALVE
. CHECK WIRING
. REPLACE DUAL CONTROLLER
REPLACE RELIEF VALVE
. INCREASE STORED WATER
TEMPERATURE AND CONFIRM
PROPERLY SIZED APPLICATION
. REMOVE CONTAMINANTS.
. SUPPLY CLEAN COMBUSTION
AIR.
. ADD WATER HAMMER
ARRESTOR.
. REDUCE WATER PRESSURE.
. REMOVE UNNECESSARY CHECK
VALVES.
ADD THERMAL EXPANSION TANK.
SCHEDULE ANODE CHECKS -
REPLACE AS NEEDED.
SUPPORT VENTING
EFFIKAL-REPLACE DAMPER CONTROL
ASSEMBLY
SEE STEP 10A
Services Switch may bypass problem until
replacement part is received. (EFFIKAL –
REPLACE DAMPER CONTROL ASSEMBLY
REPLACE IID STEP 12
REPLACE CABLE STEP 13
41
SOLUTION