STEP 13
STEP 13. PILOT SPARK TEST. Visually check for spark at the pilot assembly.
Note: The pilot burner mounts on the left side of the main burner.
IF
The igniter is not sparking:
Sparking is present:
Power To Module May Be Interrupted To Reset .
90 sec.
Call for
Sparking
heat
Technical Training Department
Ashland City, TN ©2003
SBD TANK TYPE HEATERS
SERVICE HANDBOOK
PILOT SPARK TEST
Trial for Ignition
5 min.
90 sec.
No
Sparking
Sparking
33
THEN
Check for:
A 7/64" spark gap
Spark cable continuity
Ground cable continuity
Go to step 14.
5 min.
90 sec.
No
Sparking
Sparking
Continuous
Trial
Sequence