Pc Board - State Water Heaters SandBlaster SBD71 120 Service Handbook

Sbd71 120 through sbd85 500
Table of Contents

Advertisement

STEP 4
D
a
m
p
D
a
m
p
STEP 4. INSPECT THE DAMPER. Lower the thermostat setting so the unit will not be
calling for heat, then inspect the damper.
IF
If the damper is open:
If the damper is closed:
Note: If the water temperature in the tank is below 120 degrees F, temporarily disconnect the
jumper wire between the high limit and thermostat to simulate a satisfied thermostat.
STEP 5
STEP 5. CHECK THE PC BOARD. Test for 24 VAC between the black PC board wire
connection and ground.
IF
24 VAC is not present:
24 VAC is present:
Technical Training Department
Ashland City, TN ©2003
SBD TANK TYPE HEATERS
SERVICE HANDBOOK
e
r
C
l
o
s
e
d
e
r
C
l
o
s
e
d
CHECK THE PC BOARD
INSPECT THE DAMPER
THEN
Go to step 5.
Go to step 7.
THEN
Check the black wire connections
between PC Board and high limit.
Go to step 6.
22
D
a
m
p
e
r
O
p
e
n
D
a
m
p
e
r
O
p
e
n