4.27
Ascertaining that the discharge plug is de-energized
Warning
Risk of injury The measuring points could be live.
–
Use personal protective clothing and comply with the safety measures.
4.28
Performing an equipotential bonding check (KTM PowerPack installed)
Warning
Risk of injury The measuring points could be live.
–
Use personal protective clothing and comply with the safety measures.
4.29
Performing an equipotential bonding check (KTM PowerPack installed)
Warning
Risk of injury The measuring points could be live.
–
Use personal protective clothing and comply with the safety measures.
Condition
The KTM PowerPack has been removed.
Main work
–
Prepare the special tool for measurement.
AVL DITEST HV Safety 2000 (70029068000)
–
Start software HV Safety.
–
Select "Zero-potential".
–
Follow the instructions in the HV Safety Owner's Manual.
309699-10
Finishing work
–
Mount the protection cap.
Condition
The KTM PowerPack has been removed.
–
Prepare the special tool for measurement.
AVL DITEST HV Safety 2000 (70029068000)
–
Start software HV Safety.
–
Select "Equipotential bonding check".
–
Follow the instructions in the HV Safety Owner's Manual.
309699-10
Condition
The KTM PowerPack has been removed.
(
p. 19)
WORK 4
37