Software Installation Procedure Outlined - ABB CAP 501 Installation And Commissioning Manual

Table of Contents

Advertisement

CAP 501
Installation
3.2
14
Installation and Commissioning Manual
SYS 500 8.4.2A or older.
COM 500 2.0A or older.
If you have either of these product versions installed on your computer, please take
into account, that the installation of CAP 501 invalidates SYS 500 versions 8.4.2A and
older and COM 500 versions 2.0A and older. These products will not be operable after
the installation of CAP 501. To continue using the SYS 500 and COM 500 products,
you must upgrade them according to Table 6.
Product
SYS 500
COM 500
Table 6.
Required SYS 500, COM 500 updates.
The CAP 501 installation notifies you, if it detects a SYS 500 or a COM 500 version,
which should be upgraded. You are also provided the option to cancel the installation
without modifying the computer's configuration.
Note! If you are unsure about the possible effects of CAP 501 installation on the SYS
500 and/or COM 500, it is recommended that you do not install CAP 501.

Software installation procedure outlined

When you have started the CAP 501 installation, first it gathers the following
information from your system:
Operating system
User rights
Current version
Status of the MicroSCADA service
Incompatible kernel revisions of SYS 500 and COM 500
Incompatible version
8.4.2A or older
2.0A or older
If you are not running Windows NT 4.0, the installation
notifies you, that it can not continue.
If you have logged on with insufficient user rights, you are
prompted to exit the installation and to logon to Windows
NT using an account having Administrator rights.
If a version of CAP 501 already has been installed, the
installation suggests to use the destination drive of the
existing installation. Otherwise the installation looks for the
first suitable destination drive, a physical NTFS formatted
hard disk drive, and uses it as the default destination drive.
If the installation detects that the MicroSCADA service is
running, you are prompted to exit the application, that
utilizes the service. You are not allowed to continue with the
installation while the service is executing.
Installations of SYS 500 and COM 500, that are known to
contain incompatible kernel revisions are detected. Provided,
that such product versions are detected to be installed and
superseding versions with compatible kernel of SYS 500 or
COM 500 are not detected on the computer, you are
prompted whether or not to continue the CAP 501
installation.
1MRS751270-MEN
Compatible version
8.4.3 or newer
3.0 or newer
ABB Automation

Advertisement

Table of Contents
loading