Assembly, Connection and Putting into Operation

5.1.1 Assembly on a pipeline

Mount the DL230 to a pipeline using an A2 universal brack-
et with a pipe clamp (see Appendix) as well as correspond-
ing cylinder screws.
III. 6
1. Screw into place with the aid of two self-tapping screws for plastic 4x13
mm (III. 6: 1 ) cylinder screws, insert the A2 universal bracket in the
boreholes provided (III. 6: 3 ) on the DL230 (III. 6: 2 ).
2. Tighten the screws so that the bracket is sitting in a fixed position.
3. The A2 universal bracket (III. 6: 3 ) and the device (III. 6: 2 ) should be
fastened to the pipeline (III. 6: 5 ) using the pipe clamp (III. 6: 4 )
4. The device should be mounted on the pipeline in such a way that it is in
a fixed position and cannot fall down or twisted.
WARNING!
When using longer self-tapping screws then there is a risk
of leaks in the housing
2
3
1
4
5
35