C. Blower
Service Part: SRV7000-868
1. Ensure that the fire is out and the appliance is cool to
the touch.
2. Remove the door by lifting the door up and off of
the hinges; set aside (Figure 23.1).
3. Remove the fascia by lifting up and off of the appliance;
set aside (Figure 23.1).
4. Disconnect the wires from the blower (Figure 23.2).
5. Remove the 2 screws from the hold down bracket and
pull the blower and bracket forward.
6. Remove the blower from the hold down bracket.
7. Re-install in reverse order. Be certain that the hold down
bracket's screws are completely seated in the grommets.
Insert the locating tab in the hold down bracket into the
placement slot.
CAUTION!
Shock Risk.
Do NOT remove grounding prong
from plug.
Plug directly into properly grounded 3
prong receptacle.
Route cord away from appliance.
Do NOT route cord under or in front
of appliance.
Figure 23.1
Figure 23.2
August 23, 2019
D. Snap Disc
Service Part: SRV230-0470
1. Ensure that the fire is out and the appliance is cool to
the touch.
2. Remove the door by lifting the door up and off of
the hinges; set aside (Figure 23.1).
3. Remove the fascia by lifting up and off of the appliance;
set aside (Figure 23.1)
4. Remove the 2 screws from the blower access
assembly and slide assembly away from the appliance.
5. Using a Phillips head screw driver, remove the 2
screws from the snap disc and lift the snap disc off of
the mounting bracket. Disconnect the wires and replace
with new snap disc and re-connect the wires.
6. Slide the blower assembly back into position and
secure with the 2 mounting screws.