3

Maintenance and Service

A. Quick Reference Maintenance Guide
When properly maintained, your fireplace will give
you many years of trouble-free service. Contact your
dealer to answer questions regarding proper operation,
troubleshooting and service for your appliance. Visit
www.quadrafire.com/owner-resources
troubleshooting, FAQs, use & care videos.
Baffle & Blanket
Blanket
Baffle
Blower
Chimney System
Firebrick & Ash Removal
Door & Glass Assemblies
Door Handle
August 23, 2019
to view basic
Frequency
MONTHLY
or after
every cord
of wood
YEARLY or
After Every
4 Cords of
Wood
EVERY 2
MONTHS
or After
Every 4
Cords of
Wood
WEEKLY or
After Every
25 Loads of
Wood
WEEKLY or
After Every
25 Loads of
Wood
WEEKLY or
After Every
25 Loads of
Wood
These are generic drawings and may not represent your model.
Allow the appliance to completely cool down before
performing any cleaning or maintenance. Start the
first inspection after the first 2 months of use, or if
performance changes, and adjust your schedule
accordingly. Maintenance is required for safe operation
and must be performed to maintain your warranty.
Baffle and blanket placement is critical to heat output, efficiency
and overall life of the appliance. Make sure the baffle is pushed all
of the way to the back of the firebox and the blanket is laying flat.
Inspect baffle for cracks.
Vacuum the blower impellers.
The chimney and chimney cap must be inspected for soot and
creosote every two months during the burn season or more
frequency if chimney exceeds or is under 14-16 ft (4.3m-4.8m)
measured from bottom of appliance.
This will prevent pipe blockage, poor draft, and chimney fires.
Always burn dry wood to help prevent cap blockage and
creosote build-up.
Ashes must be cool before you can dispose of the ashes in a non-
combustible container.
Firebrick is designed to protect your firebox. After ashes are
removed, inspect the firebrick and replace firebricks that are
crumbling, cracked or broken.
Keep door and glass gasket in good shape to maintain good
burn. To test: place a dollar bill between the appliance and door
and then shut the door. If you can pull the dollar out, remove one
washer from door handle behind latch cam and try again. If you
can still pull it out, replace the door gasket.
Check the glass frame for loose screws to prevent air leakage.
Check glass for cracks.
Check the door latch for proper adjustment. This is very important
especially after the door rope has formed to the appliance face.
Check door handle for smooth cam operation.
7095-803C
EXPEDITION II INSERT
CAUTION
Task
17

Hide quick links: