3 Keysight SD1 Command Reference
Name
moduleID
triggerBehavior
PXItrigger
skew
errorIn
Outputs
moduleIDout
errorOut
C
int SD_AIN_clockResetPhase(int moduleID, int triggerBehavior, int PXItrigger, double
skew);
C++
int SD_AIN::clockResetPhase(int triggerBehavior, int PXItrigger, double skew);
Visual Studio .NET, MATLAB
int SD_AIN::clockResetPhase(int triggerBehavior, int PXItrigger, double skew);
Python
int SD_AIN::clockResetPhase(int triggerBehavior, int PXItrigger, double skew);
LabVIEW
clockResetPhase.vi
M3601A
Available: No
3. 3. 2. 28 DAQbufferPoolConfig
Configures buffer pool that will be filled with the data of the channel to be transferred
to PC.
66
Description
(Non-object-oriented languages only) Module identifier,
returned by function
open on page 28
Trigger behaviour
PXI trigger number
Skew between PXI CLK10 and CLKsync in multiples of 10 ns
(LabVIEW only) If it contains an error, the function will not
be executed and errorIn will be passed to errorOut
(LabVIEW only) A copy of moduleID
Keysight SD1 Command Reference on page 23
Keysight M3100A/M3102A PXIe Digitizer User's Guide