Hide thumbs Also See for Vertex M:
Table of Contents

Advertisement

3. Open the side of the Analyzer by unscrewing the 4 thumbscrews at the top of the left side.
4. Approximately 20 seconds after the Ethernet Cable has been disconnected, the Analyzer will
recognize that it has lost communications with the DAq and activate the "Manual Override" button
shown in
Figure
the LED status flash pattern shown in Table 6-1.
To reset faults and alarms:
Press and hold button for 1-3 seconds.
To Put Analyzer into Monitor mode:
Press and hold button for 4-9 seconds
To Exit Monitor and Open Gate:
Press and hold button for 10 seconds and above
5. Close and reattach the Analyzer cover, reconnect the Ethernet communications cable, and then slide
the Analyzer into the cabinet.
Section 6 - Troubleshooting
6-1. The LEDs on the front of the Analyzer will flash to show a Maintenance Fault per
Figure 6-5. Analyzer
6-22