5. Transport and Mounting

5.2.3 Electrical connection

The double drive is designed for alternating current; see
section 4.1 "Technical Data". According to the power
intake (see name plate), a shockproof socket or a
protective device according to the relevant and / or
country-specific provisions (only to be installed by
electricians) must be provided on site.
Danger
Danger from electric shock!
Before connecting the double drive, among
others correspondence of the electricity type
and mains voltage with the information on the
name plate of the mains unit must be
observed.
Place the cable properly; see section 3 "Safety"
and section 5.2 "Mounting".
Only plug the mains plug into a matching socket.
Observe proper cable routing of the mains connection and
the cable of the handset
16
16

5.2.4 Connection of the block battery

Battery compartment

Fig. 16: Block battery

To make it possible to move to the lying position in any case
of power outage, the double drive has an emergency lowering
function that is permitted by an integrated 9V block battery.
Remove the protective film of the 9V block battery (type
6LR61). Connect the battery to the plug in the battery
compartment.
Now return the correctly connected block battery into the
provided battery compartment.