6.2.4

Terminal box

The type designation of the terminal box for connecting the power cables can be found in the
technical data. An illustration can be found in Chapter "Spare parts" (Page 91).
The maximum conductor cross-section that can be connected and the permissible cable
external diameter are listed in the "Technical data and drawings" section. The connecting
cables can be sealed and secured at every entry point into the terminal box, using the sealing
insert supplied.
See also
Technical data and drawings (Page 101)
Rotating the terminal box
Depending on the particular version, the terminal box can be rotated. It can then be rotated
through increments of 90° corresponding to the connection direction.
If necessary, contact your Service Center (Page 99).
6.2.5

Connecting the grounding conductor

The grounding conductor cross-section of the machine must be in full conformance with the
installation specifications and to IEC 60034-1.
There is a hexagon bolt with a flat washer and a spring washer on the stator frame at the
designated connecting point for the grounding conductor.
SIMOTICS HV C 1NA14544WA600AG0-Z
Operating Instructions 06/2018
External conductor cross-section S
mm²
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
Electrical connection
Grounding conductor cross-section
mm²
4
6
10
16
25
25
25
35
50
70
70
95
120
150
185
6.2 Preparation