Maintenance
9.3 Corrective Maintenance
Install the V ring
1. Grease the axial sealing surface. The shaft seating remains ungreased.
2. Push the V ring
Install the protective ring for IP56 degree of protection
For degree of protection IP56, the V ring for the outer bearing seal is fitted with a sheet steel
protective ring
1. Push the protective ring onto the shaft.
2. Verify that the ring is sufficiently pretensioned. Replace the protective ring, if necessary.
3. Position the protective ring so that one of the longitudinal grooves meets the corresponding
9.3.4.4

Installing felt rings for the inner bearing seal

Depending on the particular version, the motor is equipped with a felt ring in the inner bearing
cover. The felt ring prevents dust and grease from entering the interior of the machine.
Procedure
● Before installing new felt rings in the bearing cover, soak them in hot oil (approximately
● Place the felt ring into its notch on the bearing cap and push the bearing cap onto the shaft.
88
V ring
Mounting aid washer
Protective ring
Figure 9-2
Install the V ring
onto the shaft using an assembly disk
The V ring is in the correct axial position when the face surface is flush with the outer edge
of the V ring.
in the bearing cover.
water separation groove at the bottom in the bearing cover flange or end shield.
80°C), such as DIN 51517‑C100 lubricating oil.
.
SIMOTICS HV C 1NA14544WA600AG0-Z
Operating Instructions 06/2018