11. Technical data

Sensor
Housing material
Protection category
Ambient operating temperature
Max. operating pressure
Operating frequency
Transmission power
Weight
Dimensions
Measuring accuracy
Field housing transmitter
Power supply
Power consumption
Protection category
Ambient operating temperature
Dimensions
Weight
Interface
Cable screw connectors
Connection terminals cable cross-section
Current output
Switch output measurement alarm
Data backup
Pulse output
DIN rail transmitter
Power supply
Power consumption
Protection type
Ambient operating temperature
Dimensions
Weight
Interface
DIN rail fastening
Connection terminals cable cross-section
Current output
Switch output measurement alarm
Data backup
EN 19/05/2015
Stainless steel 1.4571
IP 65, dust explosion zone 20 or gas explosion zone 1 (optional)
Sensor tip:
-20 ... + 80 °C
Sensor element:
0 ... + 60 °C
1 bar, optional 10 bar
K band 24.125 GHz, ± 100 MHz
Max. 5 mW
1.3 kg
Ø 60, Ø 20, L 271 mm
± 2 ... ± 5 % (in the calibrated measuring range)
110/230 V, 50 Hz (optional 24 V DC)
20 W / 24 VA
IP 65 to EN 60 529/10.91
-10 ... +45 °C
258 x 237 x 174 (W x H x D)
Approx. 2.5 kg
RS 485 (ModBus RTU) / USB
3 x M16 (4.5 - 10 mm Ø)
0,2 – 2,5 mm² [AWG 24-14]
4 ... 20 mA (0 ... 20 mA), load < 500 W
Relay with switchover contact - Max. 250 VAC, 1 A
Flash memory
Open Collector - max. 30 V, 20 mA
24 V DC ± 10 %
20 W / 24 VA
IP 40 to EN 60 529
-10 ... +45 °C
22.55 x 90 x 118.8 (W x H x D)
Approx. 350 g
RS 485 (ModBus RTU) / RS 232C
DIN 60715 TH35
0,2 – 2,5 mm² [AWG 24-14]
4 ... 20 mA (0 ... 20 mA), load < 500 W
Relay with switchover contact - Max. 250 VAC, 1 A
Flash memory
Optional: -20 ... + 200 °C