Setting The Heating On The Econo Model; Manual Bypass Damper - Swegon CASA W3 Smart Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

4.3 Setting the heating on the
Econo model
The setting of the Econo model's water-heat-
ed air heater for reheating is performed with a
thermostat that is placed inside the ventilation
unit. The thermostat setting positions
correspond to the following temperatures:
Together with the W5 ventilation unit, you
can use a separate water heated air heater
which is installed in a duct. The air heater is
commissioned and set using a Smart control
panel. Commissioning and setting are
described in the installation, operation and
maintenance instructions for the air heater.
The duct mounted air heater is optional
equipment: SDHW160.

4.4 Manual bypass damper

The W3/W4 ventilation unit is also available
with a manual summer bypass damper for the
heat exchanger. The bypass of air past the heat
exchanger is a built-in function in the ventila-
tion unit. This function is used to prevent heat
recovery when it is hot during the summer.
Open the bypass damper in the extract cham-
*
=
8 °C
ber to activate the bypass. Pull the locking pin
1
=
11 °C
ring and turn the damper lever to its lower
2
=
14 °C
position to do this. If the damper is open, the
3
=
17 °C
electric air heater for reheating is disabled.
4
=
20 °C
(5
=
23 °C)
When the next heating season begins, you
(6
=
26 °C)
simply close the bypass damper, so that the
locking pin aligns with the appropriate hole.
Winter mode is marked on the ventilation unit
with a snowflake symbol.
Winter
Summer
Swegon reserves the right to alter specifications.