4.6.2 Auto humidity control

The function is available only on models
equipped with a RH sensor. The function
increases the ventilation level steplessly
according to the normal moisture load caused
by a person, for example, when a shower
adds extra moisture to the residence. If the
relative humidity of residence rises above 60%
over a longer period, the set airflows must be
increased, and the reason for the high level of
moisture investigated.
The function level can be set from Smart
shortcuts / Auto humidity control menu.
Auto humidity control
RH now
Boost limit
Full boost limit
Sauna function
Sauna boost
The value
"RH
now", the current moisture
level, is shown on the settings menu.
The automatic humidity system measures
the daily average value in the extract air and
compares this with the current value. The
ventilation starts to be boosted variably when
the humidity has risen as much as the
limit
value.
sauna limit
If you put automatic
the ventilation is boosted with the set value
during the sauna. This function prevents any
disruptive variations in the fan speeds while
the sauna is working.

4.6.3 Auto Air Quality control

The function is available only on models
equipped with a VOC sensor. The function
increases the ventilation level steplessly ac-
cording to the VOC level in the home.
The function can be activated and the level
can be set from Smart shortcuts / Auto Air
Quality control menu.
AQ now
Boost limit
Full boost limit
Filter time
The settings menu shows the value
now"
tion is set by specifying the boost limits where
you want the ventilation boost to start and
the value at which you want the ventilation
unit to reach maximum boost. Appropriate
values can be established based on the
now"
30 %
If it seems that the ventilation system reacts
too quickly to changes in the air quality level,
5 % + RH
you can increase the
30 % + RH

4.6.4 Summer night cooling boost

5 %
Summer night cooling effect is enhanced with
boosting the ventilation if supply air tempera-
ture is relatively low.
The function can be activated and the level
can be set from Smart shortcuts / Summer
night cooling menu.
Boost
Level
into service,
Boost
The function is working automatically when
summer night cooling is active. Boost level can
be set to Off, Low, Normal, High or Full. The
default setting is Low.
Note. User setting can be defined by ad-
vanced user from Smart functions settings.

4.6.5 Smart function diagnostics

Smart function operation can be checked
from Main menu / Diagnostics / Smart func-
tions view.
Swegon reserves the right to alter specifications.
Auto Air Quality control
the current air quality level. The func-
value shown in the menu.
filtering
Summer night cooling
620 ppm
800 ppm
1400 ppm
1 min
"AQ
"AQ
time.
Normal
Low
EN