Carrier DesertMaster 50TJM Operation And Maintenance page 21

Package rooftop units
Table of Contents

Advertisement

Fan Performance Table - 7 (cont)
Unit - 50TJM - 24 - 19 Tons - 50Hz (Standard Motor)
Air Flow Rate
0.2
(CFM)
RPM
KWI
5000
583
1.30
5500
617
1.62
6000
654
2.01
6500
689
2.44
7000
725
2.95
7500
761
3.51
Unit - 50TJM - 24 - 19 Tons - 50Hz (Standard Motor) (cont)
Air Flow Rate
1.2
(CFM)
RPM
KWI
5000
856
2.52
5500
874
2.91
6000
893
3.37
6500
913
3.87
7000
936
4.44
7500
959
5.07
Bold, Italics - Standard Motor and Drive Package
Unit - 50TJM - 24 - 19 Tons - 50Hz (High Efficiency Motor)
Air Flow Rate
0.2
(CFM)
RPM
KWI
5000
583
1.25
5500
617
1.57
6000
654
1.94
6500
689
2.36
7000
725
2.84
7500
761
3.39
Unit - 50TJM - 24 - 19 Tons - 50Hz (High Efficiency Motor) (cont)
Air Flow Rate
1.2
(CFM)
RPM
KWI
5000
856
2.43
5500
874
2.81
6000
893
3.25
6500
913
3.73
7000
936
4.28
7500
959
4.89
Bold , Italics - High Efficiency Motor and Drive Package
Legend:
RPM - Revolutions Per Minute
KWI - Kilo Watts Input to Motor
BHP - Brake Horsepower Input to Fan
CFM - Cubic Feet per Minute
Notes:
1. Do not adjust motor rpm such that motor maximum bhp and/or watts is exceeded at the maximum operatin cfm.
2. Static Pressure (i.e Filters) must be added to external static pressure before entering fan performance table.
3. Interpolation is permissible. Do not extrapolate.
4. Fan performance is based on wet coils, clean filters and casing loses.
5. Extensive motor and drive testing on these units ensures that the full brake horsepower and watts range of the motor can be utilized with confidence. Using
your fan motors up to the watts or bhp rating shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected.
6. Bold data shows the range of air flow rate for unit management system, other rpms require field-supplied drive.
7. Use of field-supplied motor may affect wiring size. Contact your Carrier representative for details.
8. Conversion - Bhp to KWI
Bhp X 0.746
KWI=
Motor efficiency
Available External Static Pressure (in. wg)
0.4
BHP
RPM
KWI
BHP
1.48
642
1.51
1.73
1.86
672
1.86
2.13
2.30
704
2.26
2.58
2.80
735
2.71
3.10
3.37
768
3.22
3.69
4.02
802
3.80
4.35
Available External Static Pressure (in. wg)
1.4
BHP
RPM
KWI
BHP
2.88
906
2.80
3.20
3.34
920
3.20
3.67
3.85
938
3.67
4.20
4.43
956
4.19
4.79
5.08
976
4.77
5.46
5.80
998
5.41
6.20
Available External Static Pressure (in. wg)
0.4
BHP
RPM
KWI
BHP
1.48
642
1.46
1.73
1.86
672
1.79
2.13
2.30
704
2.18
2.58
2.80
735
2.61
3.10
768
3.11
3.69
3.37
4.02
802
3.67
4.35
Available External Static Pressure (in. wg)
1.4
BHP
RPM
KWI
BHP
2.88
906
2.70
3.20
3.34
920
3.09
3.67
3.86
938
3.54
4.20
4.43
956
4.04
4.80
5.08
976
4.60
5.46
5.81
998
5.22
6.20
0.6
RPM
KWI
BHP
RPM
698
1.75
2.00
754
724
2.10
2.41
775
752
2.51
2.88
800
781
2.98
3.41
826
811
3.51
4.02
854
842
4.11
4.70
882
1.6
RPM
KWI
BHP
RPM
954
3.08
3.53
998
966
3.50
4.01
1009
980
3.98
4.56
1023
998
4.51
5.17
1038
1016
5.11
5.85
1055
1035
5.77
6.60
1073
0.6
RPM
KWI
BHP
RPM
698
1.69
2.00
754
724
2.03
2.41
775
752
2.42
2.88
800
781
2.88
3.41
826
811
3.39
4.02
854
842
3.96
4.70
882
1.6
RPM
KWI
BHP
RPM
954
2.97
3.53
998
966
3.38
4.01
1009
980
3.84
4.56
1023
998
4.36
5.17
1038
1016
4.93
5.85
1055
1035
5.56
6.60
1073
Page 21
0.8
1.0
KWI
BHP
RPM
KWI
1.99
2.28
805
2.25
2.36
2.70
825
2.63
2.79
3.19
847
3.07
3.27
3.74
871
3.57
3.81
4.36
895
4.12
4.42
5.06
921
4.74
1.8
2.0
KWI
BHP
RPM
KWI
3.37
3.86
1040
3.67
3.81
4.36
1052
4.13
4.30
4.93
1064
4.63
4.85
5.55
1077
5.20
5.46
6.25
1094
5.82
6.13
7.02
1110
6.50
0.8
1.0
KWI
BHP
RPM
KWI
1.92
2.28
805
2.17
2.28
2.70
825
2.54
2.69
3.19
847
2.96
3.15
3.74
871
3.44
3.68
4.36
895
3.98
4.26
5.06
921
4.57
1.8
2.0
KWI
BHP
RPM
KWI
3.25
3.86
1040
3.54
3.67
4.36
1052
3.98
4.15
4.93
1064
4.47
4.68
5.56
1077
5.01
5.26
6.25
1094
5.61
5.91
7.02
1110
6.27
BHP
2.58
3.01
3.51
4.08
4.72
5.43
BHP
4.20
4.72
5.30
5.95
6.66
7.44
BHP
2.58
3.01
3.52
4.08
4.72
5.43
BHP
4.20
4.72
5.31
5.95
6.66
7.44

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents