Utility Menu; Selecting The Aes/Ebu Output Reference Level (Aes/Ebu Lvl@Mic); Selecting The Sync Signal (Sync Source); Terminating The Sync Signal (Word Sync 75Ohm) - Sony DWR-S02DN Operating Instructions Manual

Digital wireless receiver
Table of Contents

Advertisement

UTILITY Menu

For details on menu operation, see "Basic Menu
Operations" on page 11.
The UTILITY menu includes items related to the basic
receiver settings, including meter displays.
These functions and parameters are explained here.
Underlined items are the factory setting.
Menu name
Item to be set
Note
The functions indicated by "ADAPTER" (from the AES/
EBU LVL@MIC function to the ANALOG OUTPUT1
function) in the upper-right corner are related to the AES/
EBU output when the receiver is used in conjunction with
the optional DWA-01D/F01D wireless adapter. The
function does not operate even when used with a
compatible Sony slot-in type camcorder.
Selecting the AES/EBU Output
Reference Level
Selects reference level for the AES/EBU output of the
optional DWA-01D/F01D wireless adapter.
The setting of this function is invalid when the audio input
level of the sending transmitter is set to LINE (–20 dBFS
headroom signal).
Note
The function does not operate for analog output.
– 36 dBFS LINEAR: The audio signal from the
transmitter is output with a headroom of 36 dB.
– 20 dBFS LIMITER: The reference level is changed to
–20 dBFS in conformity with the normal AES/EBU
interface and the audio signal from the transmitter is
compressed.
– 20 dBFS ST LIMIT: The reference level is changed to
–20 dBFS (as in the –20 dBFS LIMITER mode above) and
audio signal compression is linked for tuner 1 and tuner 2.
Select this setting when sending stereo audio signals using
2 transmitters.
Selecting the Sync Signal
(SYNC SOURCE)
Selects the sync signal source for the receiver when it is
attached through the optional DWA-01D/F01D wireless
adapter. The receiver supports an external sync signal
(word clock) of 32 kHz –6% to 96 kHz +6%.
Function name
(AES/EBU LVL@MIC)
For details on locking the sync signal, refer to the
operating instructions supplied with the adapter.
INTERNAL: The internal sync signal (48 kHz) is used.
AUTO: The external sync signal is used on a priority
basis. When there is no external sync signal input, the
internal sync signal is used automatically. The currently
selected sync signal is displayed "INTERNAL" or
"EXTERNAL."
EXTERNAL: Synchronization with an external word
clock signal. The current synchronization status is
displayed "UNLOCK" or "LOCK."
Note
When "EXTERNAL" is selected, digital signals and
analog signals will be output only if there is an external
word clock signal input.
Terminating the Sync Signal
(WORD SYNC 75ohm)
This function provides termination for the WORD SYNC
connector on the DWA-01D/F01D wireless adapter.
ON: 75-ohm termination is added.
OFF: 75-ohm termination is not added.
Note
When the receiver is turned off, the termination is released.
Selecting Output 1
Selects the OUTPUT1 connector of the DWA-01D/F01D
wireless adapter.
When the OUTPUT2 connector of the adapter is being
used for AES/EBU output, the OUTPUT1 connector can
be used for sub-output.
RX1: Outputs the audio signal received on tuner 1.
RX2: Outputs the audio signal received on tuner 2.
RX1+2: Mixes and outputs the audio signals received on
tuners 1 and 2.
Showing the Accumulated Use Time
(TIME)
You can display the accumulated battery use time as a
rough estimate of total receiver usage.
The factory setting is "00:00".
Resetting the accumulated time indication
1
Hold down the SET button until the time indication
flashes.
2
Press the – button so "00:00 RESET" appears, and
then press the SET button.
12
(ANALOG OUTPUT1)

Advertisement

Table of Contents
loading

Table of Contents