6/ CONFIGURATION

This menu is used to determine all the settings adapted to your installation.
❶To enter configuration mode, press the MODE button for 10 seconds until the
screen displays CF01.
❷Press + or - to set.
❸Briefly press MODE to go to the next menu.
Press MODE or wait 5 seconds to exit.
CF01 - Correcting the temperature measured
Setting from -5°C to +5°C
Example: If the temperature displayed by the unit is 15°C and the actual
temperature (thermometer) is 16°C, set +1°C.
CF02 - Settings lock
0
No locking (default setting)
1
Total locking
2
Partial locking. Modification of the temperature setting at +/-2°C
The screen will display '____' if it is locked
To unlock (selection 1 and 2), simultaneously press + or - the buttons for 10
seconds.
CF04 - Frost protection mode temperature setting
Setting of 5°C to 15°C. Default value: 10°C.